IC Number in Schematic |
U6010 |
Name and Function of IC |
Extra voltage protector |
Technical Number |
KTS1682 |
IC Manufacturer |
KINETIC |
IC Package |
WLCSP , 12P |
Malfunctios related to IC :
1. Failure to charge and detection of the charger
2. OTG malfunction
Repair flowchart related to this section :
The C6040 part has a voltage of 5 volts, so if there is no voltage, replace and check the U6010 IC.